NVA Quick Start

This guide walks you through alignment with NVA – Nozzle Visual Aligner in a few minutes.

Advisory

  • Review the full User Manual or watch the tutorial video before operating.

  • Use the cutting head’s red guide light only during alignment—do not apply cutting power.

  • Follow your site’s laser-safety procedures and all local regulations.

Overview of the NVA

1. Unbox NVA & Power Testing

  • Open the box and take out the NVA.

  • Open the battery compartment on the underside of the NVA.

  • Insert two 14500 Li-ion batteries (3.7 V each), observing (+/–) polarity.

  • Close the compartment.

  • Press the power button to turn on the NVA; confirm the status LED lights on.

No 14500 batteries?

Connect the included USB-C cable from the NVA to a power bank or power adaptor (5V/3A), then press the power.

2. Before you start

1

2.1 NVA Pre-alignment Preparation

  • Power on the NVA and confirm the status LED is steady.

  • Place the NVA horizontally directly under the laser cutting head; placing it on a metal sheet is recommended.

  • Check the built-in bubble level is centered. If the unit isn’t level, shim the appropriate corner(s) (e.g., with paper) until level to avoid affecting alignment accuracy.

2

2.2 Laser Cutting Head Preparation

  • Adjust the laser head Z-axis so it is positioned around 10 mm above the NVA.

  • Install the dedicated alignment nozzle (included with the NVA package) onto the laser cutting head.

  • Turn on the cutting head’s red guide light and ensure the red dot fully enters the central.

3

2.3 Connect & Open Web App

Overview - NVA connects via Wi-Fi. After powering on, it automatically creates a network named NVA-[Serial Number]. Join this network on your phone to perform alignment.

Connect Your Phone

  1. Open your phone’s Wi-Fi settings and select the network NVA-[Serial Number].

  2. Tap Join. Password: 88888888 (eight eights).

  3. Once connected, open the alignment interface in either of the following ways:

Method 1 — Enter URL

Open your browser and go to http://192.168.0.1:8088.

Method 2 — Enter URL

Use your browser’s QR code scanner to scan the sticker on the top of the NVA unit and open the link to the alignment page.

Start Nozzle Align

AUTO MID的区别

1

Step 1 — Capture Nozzle (Red Guide Light OFF)

  • Open the NVA lens protective cover.

  • Turn OFF the red guide light.

  • Adjust the nozzle height until the nozzle image is sharp.

  • Tap “Step 1: Capture Nozzle (Red OFF)”.

  • Indicator: When alignment succeeds, a yellow crosshair ring will appear, as shown in following image.

If not shown or unstable: adjust the cutting head position or reposition the NVA until the yellow corsshair ring appear.

Step 1 completion criterion: The yellow alignment ring—and its center—are perfectly concentric with the nozzle center.
2

Step 2 - Adjust Red-Light Focus (Red Light ON)

  • Turn ON the red guide light.

  • Tap “Step 2: Adjust Red Light (Red ON)”.

  • Adjust the red-light focus value in the software—recommended presets -5 mm, -10 mm, -15 mm—until the spot becomes stable, with concentrated brightness and a sharply defined circular edge

If the alignment image is unclear, check the NVA lens for dust. If cleaning is needed, use a dedicated laser-head cleaning kit only.

3

Step 3 - Manual Coaxial Alignment

  • Tap “Step 3: Coaxial Manual Tuning”.

  • Use the coaxial adjustment screws on the cutting head to align.

  • Alignment is complete when the red-dot center coincides with the nozzle center (rings/crosshair concentric). (Auto mode) Coaxial alignment is complete when the diff_X and diff_Y indicators in the top-right of the screen both read 0.

4

Step 4 - Finish

  • Remove the NVA device and power it off.

  • Remove the dedicated NVA alignment nozzle and reinstall your original nozzle.

Last updated